Part Number Hot Search : 
CD4715 10129126 C4703 AD588BQ KK4502BD 74HC3G14 D954420 MGF0909
Product Description
Full Text Search
 

To Download CR5AS400-12 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 CR5AS
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272
Surface Mount, Phase Control SCR
5 Amperes/400-600 Volts
OUTLINE DRAWING B D G N
H C A
Description: The Powerex CR5AS SCRs are surface mounted for use in medium power control and rectification. These devices are molded silicone plastic types. Features: Surface Mount Type Glass Passivated
K J F F
E
M L
CONNECTION DIAGRAM
Easy Application to Printed Circuits High Surge On-state Current
CATHODE ANODE GATE ANODE

Applications: Static Switches Motor Control Strobe Flasher Ordering Information: Example: Select the complete six or seven digit part number you desire from the table - i.e. CR5AS-12 is a 600 Volt, 5 Ampere Phase Control SCR.
Type CR5AS VDRM/VRRM Volts 400 600 Code -8 -12
Outline Drawing (Conforms to MP-3) Dimensions A B C D E F G Inches 0.39 Max. 0.26 0.22 0.008 0.20 0.008 0.18 0.09 Min. 0.09 Millimeters 10 Max. 6.5 5.5 0.2 5.0 0.2 4.6 2.3 Min. 2.3 Dimensions H J K L M N Inches 0.06 0.008 0.040 0.035 Max. 0.035 Max. 0.31 0.020 0.004 Millimeters 1.5 0.2 1.01 0.9 Max. 0.9 Max. 0.8 0.5 0.1
P-33
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272 CR5AS Surface Mount, Phase Control SCR 5 Amperes/400-600 Volts
Absolute Maximum Ratings, Ta = 25 C unless otherwise specified
Ratings Repetitive Peak Off-state Voltage Repetitive Peak Reverse Voltage Non-repetitive Peak Reverse Voltage DC Reverse Voltage DC Forward Voltage RMS On-state Current Average On-state Current (Nominal, See Graphs) Ta = 88C I2t for Fusing, t = 8.3 msec Peak Gate Power Dissipation Average Gate Power Dissipation Peak Forward Gate Current Peak Forward Gate Voltage Peak Reverse Gate Voltage Storage Temperature Operating Junction Temperature Weight Symbol VDRM VRRM VRSM VR(DC) VD(DC) IT(RMS) IT(avg) I2t PGM PG(avg) IFGM VFGM VRGM Tstg Tj - CR5AS-8 400 400 500 320 320 7.8 5 90 33 0.5 0.1 0.3 6 6 -40 to 125 -40 to 125 0.26 CR5AS-12 600 600 720 480 480 7.8 5 90 33 0.5 0.1 0.3 6 6 -40 to 125 -40 to 125 0.26 Units Volts Volts Volts Volts Volts Amperes Amperes Amperes A2sec Watts Watts Amperes Volts Volts C C Grams
Non-repetitive Peak Surge, On-state Current One Cycle (60 Hz) ITSM
P-34
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272 CR5AS Surface Mount, Phase Control SCR 5 Amperes/400-600 Volts
Electrical and Thermal Characteristics, Tj = 25 C unless otherwise specified
Characteristics Voltage - Blocking State Peak Forward Leakage Peak Reverse Leakage Current - Conducting State Peak On-state Voltage DC Holding Current Maximum Thermal Resistance Junction-to-case Gate - Parameters Gate Current to Trigger Gate Voltage to Trigger Non-triggering Gate Voltage Symbol IDRM IRRM VTM IH Rth(j-c) IGT VGT VGD Test Conditions Tj = 125C, VD = VDRM Tj = 125C, VR = VRRM Tc = 25C, ITM = 2.5A VD = 12V, RGK = 1K , Tj = 25C - VD = 6V, RL = 60 , Tj = 25C VD = 6V, RL = 60 , Tj = 25C VD = 1/2VDRM, RGK = 1k , Tj = 125C Min. - - - - - 1 - 0.1 Typ. - - - 3.5 - - - - Max. 2.0 2.0 1.8 - 3.0 200 0.8 - Units mA mA Volts mA C/W A Volts Volts
P-35
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272 CR5AS Surface Mount, Phase Control SCR 5 Amperes/400-600 Volts
MAXIMUM ON-STATE CHARACTERISTICS
INSTANTANEOUS ON-STATE VOLTAGE, VT, (VOLTS)
3.8 3.4 3.0 2.6 2.2 1.8 1.4 1.0
Tj = 25oC
TRANSIENT THERMAL IMPEDANCE, Zth(j-c), Zth(j-a), (C/WATT)
TRANSIENT THERMAL IMPEDANCE CHARACTERISTICS (JUNCTION-TO-CASE, JUNCTION-TO-AMBIENT) 100 101 102 103 103
GATE CHARACTERISTICS
102
Tj = 25
GATE VOLTAGE, VG, (VOLTS)
JUNCTION-TO-AMBIENT
101
VFGM = 6V
PGM = 0.5W
102
PG(avg) = 0.1W
100
VGT = 0.8V IGT = 200 A
101
10-1
IFGM = 0.3A VGD = 0.1V
JUNCTION-TO-CASE
0.6 10-1
100
101
102
100 10-3
10-2
TIME, t, (s)
10-1
100
10-2 10-1
100
101
102
103
INSTANTANEOUS ON-STATE CURRENT, ITM, (AMPERES)
GATE CURRENT, IG, (mA)
MAXIMUM SURGE CURRENT FOLLOWING RATED LOAD CONDITIONS
MAXIMUM ALLOWABLE CASE TEMPERATURE, TC, (C) MAXIMUM PEAK SURGE CURRENT, ITSM, (AMPERES)
MAXIMUM ALLOWABLE CASE TEMPERATURE (SINGLE-PHASE HALF WAVEFORM)
ALLOWABLE AMBIENT TEMPERATURE VS. AVERAGE ON-STATE CURRENT (SINGLE-PHASE HALF WAVEFORM)
100
160 140 120 100 80
90 RESISTIVE, INDUCTIVE LOADS NATURAL CONVECTION
360
160 140
AMBIENT TEMPERATURE, Ta, (C)
80
120 100 80 60 40 20 0
RESISTIVE, INDUCTIVE LOADS NATURAL CONVECTION WITHOUT FIN
360
60
40
60 40 20 0 0 2 04
= 30 60
120
20
180
0 100
= 30 60 90 120 180
101
CYCLES AT 60 Hz
102
6
8
0
0.4
0.8
1.2
1.6
AVERAGE ON-STATE CURRENT, IT(avg), (AMPERES)
AVERAGE ON-STATE CURRENT, IT(avg), (AMPERES)
ALLOWABLE AMBIENT TEMPERATURE VS. AVERAGE ON-STATE CURRENT (SINGLE-PHASE HALF WAVEFORM)
MAXIMUM ON-STATE POWER DISSIPATION (SINGLE-PHASE HALF WAVEFORM)
MAXIMUM ALLOWABLE CASE TEMPERATURE (SINGLE-PHASE FULL WAVEFORM)
MAXIMUM ALLOWABLE CASE TEMPERATURE, TC, (C)
160 140
AMBIENT TEMPERATURE, Ta, (C) MAXIMUM POWER DISSIPATION, (WATTS)
16 14 12 10 8 6 4 2 0 0 2 4 6 8 0 2 4 6 8
AVERAGE ON-STATE CURRENT, IT(avg), (AMPERES) AVERAGE ON-STATE CURRENT, IT(avg), (AMPERES)
360
160
RESISTIVE LOADS
RESISTIVE, INDUCTIVE LOADS 90
180 120
140 120 100 80 60 40 20
= 30 60 90 120 180
360
120 100 80 60 40 20 0
= 30 60 90 120 180
360
RESISTIVE, INDUCTIVE LOADS NATURAL CONVECTION FIN: ALUMINUM BOARD 80 X 80 X t2.3
60
= 30
0 0 2 4 6 8
AVERAGE ON-STATE CURRENT, IT(avg), (AMPERES)
P-36
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272 CR5AS Surface Mount, Phase Control SCR 5 Amperes/400-600 Volts
ALLOWABLE AMBIENT TEMPERATURE VS. AVERAGE ON-STATE CURRENT (SINGLE-PHASE FULL WAVEFORM)
ALLOWABLE AMBIENT TEMPERATURE VS. AVERAGE ON-STATE CURRENT (SINGLE-PHASE FULL WAVEFORM)
MAXIMUM ON-STATE POWER DISSIPATION (SINGLE-PHASE FULL WAVEFORM)
160 140
AMBIENT TEMPERATURE, Ta, (C)
160 140
AMBIENT TEMPERATURE, Ta, (C)
360
16
MAXIMUM POWER DISSIPATION, (WATTS)
RESISTIVE LOADS, NATURAL CONVECTION WITHOUT FIN
120 100 80 60 40 20 0 0 0.4 0.8 1.0
= 30 60
120 100 80 60 40
RESISTIVE LOADS, NATURAL CONVECTION FIN: ALUMINUM BOARD 80 X 80 X t2.3
RESISTIVE LOADS
14 12
360
180 60 90 120
360
10 8 6 4 2 0 0 2
= 30
90 120 180
120
20
= 30 60 90 180
0 1.2 1.6 0 2 4 6 8
AVERAGE ON-STATE CURRENT, IT(avg), (AMPERES) AVERAGE ON-STATE CURRENT, IT(avg), (AMPERES)
4
6
8
AVERAGE ON-STATE CURRENT, IT(avg), (AMPERES)
GATE TRIGGER CURRENT VS. JUNCTION TEMPERATURE (TYPICAL)
GATE TRIGGER VOLTAGE VS. JUNCTION TEMPERATURE (TYPICAL)
HOLDING CURRENT VS. JUNCTION TEMPERATURE (TYPICAL)
103
GATE TRIGGER CURRENT, (tC) x 100% GATE TRIGGER CURRENT, (25C) GATE TRIGGER VOLTAGE, (tC) x 100% GATE TRIGGER VOLTAGE, (25C)
1.0
DISTRIBUTION TYPICAL EXAMPLE
HOLDING CURRENT, IH, (mA)
102
RGK = 220
0.8
102
101
DISTRIBUTION TYPICAL EXAMPLE
0.6
101
0.4
100
0.2 0 10-1 -40
100 -40
RGK = 1k
0
40
80
120
-40
0
40
80
120
0
40
80
120
160
JUNCTION TEMPERATURE, Tj, (C)
JUNCTION TEMPERATURE, Tj, (C)
JUNCTION TEMPERATURE, Tj, (C)
HOLDING CURRENT VS. GATE-TO-CATHODE RESISTANCE (TYPICAL)
BREAKOVER VOLTAGE VS. JUNCTION TEMPERATURE (TYPICAL)
BREAKOVER VOLTAGE VS. RATE OF RISE OF OFF-STATE VOLTAGE (TYPICAL)
400
Tj = 25C
x 100% BREAKOVER VOLTAGE, (tC) x 100% BREAKOVER VOLTAGE, (25C)
160
RGK = 220
x 100%
160 140 120 100 80 60 40 20 0 100 101 102 103
EXPONENTIAL WAVE Tj = 125C RGK = 220
HOLDING CURRENT, (RGK = 1k )
HOLDING CURRENT, (RGK = rk )
300
120
200
80
100
40
0 101
0 102 103 104 -40 0 40 80 120 160
GATE-TO-CATHODE RESISTANCE, RGK, (k ) JUNCTION TEMPERATURE, Tj, (C)
BREAKOVER VOLTAGE, (dv/dt = x V/ s) BREAKOVER VOLTAGE, (dv/dt = 1V/ s)
RATE OF RISE OF OFF-STATE VOLTAGE, dv/dt, (V/ s)
P-37
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272 CR5AS Surface Mount, Phase Control SCR 5 Amperes/400-600 Volts
BREAKOVER VOLTAGE VS. GATE-TO-CATHODE RESISTANCE (TYPICAL)
x 100%
REPETITIVE PEAK REVERSE VOLTAGE VS. JUNCTION TEMPERATURE (TYPICAL)
REPETITIVE PEAK REVERSE VOLTAGE, (tC) x 100% REPETITIVE PEAK REVERSE VOLTAGE, (25C)
GATE TRIGGER CURRENT VS. GATE CURRENT PULSE WIDTH (TYPICAL)
160 140 120 100 80 60 40 20 0 101 102 103 104
Tj = 125C
160
GATE TRIGGER CURRENT, (tw) x 100% GATE TRIGGER CURRENT, (DC)
104
BREAKOVER VOLTAGE, (RGK = rk ) BREAKOVER VOLTAGE, (RGK = 1k )
120
tw
103
0.1 s
80
102
40
0 -40 0 40 80 120 160
JUNCTION TEMPERATURE, Tj, (C)
101 100
101
102
103
GATE-TO-CATHODE RESISTANCE, RGK ,(k )
GATE CURRENT PULSE WIDTH, tw, ( s)
P-38


▲Up To Search▲   

 
Price & Availability of CR5AS400-12

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X